How to Flash the Bootloader and CONNECTIX firmware on the Identix RFID Readers

Use this procedure when an Identix CONNECTIX reader no longer boots, is stuck in a reboot loop, or cannot be updated through the normal update path. The recovery has two stages:

  1. Write the recovery bootloader over USB.
  2. Install the CONNECTIX firmware through the bootloader’s Wi-Fi access point.
  • A PC with Google Chrome or Microsoft Edge. Firefox and Safari do not support USB serial ports.
  • A USB data cable. Charge-only cables do not show a serial port.
  • A screwdriver to open the reader case.
  • The recovery image connectix_bootloader_vX_Y_Z_W_combined.bin and the firmware connectix_vX_Y_Z_W_ota.bin. Both are on the recovery tool page.
  • A PC, laptop or phone with Wi-Fi for stage 2.

Writing the recovery image resets the reader’s settings (network, MQTT and reader configuration). Note them before you start if the reader can still show them.

Stage 1: write the recovery bootloader (USB)

Section titled “Stage 1: write the recovery bootloader (USB)”
  1. Disconnect all power from the reader: power supply, PoE/Ethernet and USB cable.
  2. Open the case and find the BOOT button on the main board (not RST).
  3. Press and hold BOOT, connect the USB cable to the PC, wait about one second and release BOOT.

The reader is now in download mode. It runs no firmware and the LEDs may stay off. Keep the external power supply disconnected during this stage; the USB cable powers the board. See also How to put Identix RFID readers in Bootloader Mode.

With the recovery tool, click Connect, pick the reader’s port and click Write bootloader.

To do it by hand with Espressif’s esptool-js page:

  1. Leave the baud rate at the default and click Connect. Select the reader’s port, usually named USB JTAG/serial debug unit. The log must show an ESP32-S3 chip.
  2. Set Flash Address to 0x0. The page default, 0x1000, is wrong for this image.
  3. Choose connectix_bootloader_vX_Y_Z_W_combined.bin and click Program. Wait until the log reports that the hash was verified.
  4. Click Disconnect.

Do not use Erase Flash unless a normal recovery did not work.

The recovery tool restarts the reader by itself after writing. If you wrote the image by hand, or the Identix-BL network does not appear within about 30 seconds, unplug the USB cable and plug it back in without pressing BOOT, or reconnect the normal power supply. The reader starts the recovery bootloader.

Stage 2: install the CONNECTIX firmware (Wi-Fi)

Section titled “Stage 2: install the CONNECTIX firmware (Wi-Fi)”
  1. Download the connectix_vX_Y_Z_W_ota.bin file to the PC or phone before the next step, because the reader’s network has no internet access.

  2. After a few seconds the reader creates a Wi-Fi network:

    • Network name (SSID): Identix-BL XX:XX:XX (the last three bytes of the reader’s MAC address)
    • Password: !Idntx1234

    Connect to it and stay connected even if the device warns that there is no internet. On phones, turn off mobile data or choose to keep the connection.

  3. Open http://192.168.4.1 in a browser. The Identix Firmware Installer page opens. Icons may be missing because there is no internet; this does not affect the upload.

  4. Click Choose Firmware File and select the connectix_…_ota.bin file. Only .bin files up to 3 MB are accepted.

  5. Click Upload Firmware and wait for the progress bar to reach 100%. Do not power off or disconnect the reader during the upload.

  6. When Upload Successful! appears, the reader restarts into the CONNECTIX firmware and the Identix-BL network disappears.

Close the case, reconnect the normal power supply and network, and configure the reader again.

Problem What to do
No serial port appears Try another USB data cable or USB port. Repeat download mode, holding BOOT before you plug in USB.
The flashing page cannot connect or times out Close any other program using the port (serial monitor, IDE, ESP Flash Download Tool), put the reader in download mode again and click Connect.
The Identix-BL network does not appear after stage 1 Check that the _combined.bin file was written at 0x0, and that BOOT is not pressed when powering up. Repeat stage 1.
Upload fails with “OTA write failed” or “OTA complete failed” The file is not a valid application image. Use the connectix_…_ota.bin file, not _combined.bin.
Upload fails with “File size must be less than 3MB” You selected the wrong file. Use the connectix_…_ota.bin file.
The page at 192.168.4.1 does not open Check that you are connected to the Identix-BL network, turn off any VPN, and type http:// explicitly (not https://).
The reader still does not work after recovery Repeat stage 1 with a full flash erase first (in the recovery tool: Advanced › Erase the whole flash), then repeat stage 2.